HCM(YL)
XCSPA792
Delivery time:6 weeks
	
| MAIN | |
|---|---|
| Range of product | Telemecanique Safety switches XCS | 
| Product or component type | Safety switch | 
| Component name | XCSPA | 
| Design | Compact | 
| Material | Plastic | 
| Head type | Key operated turret head | 
| Contacts type and composition | 2 NC | 
| Contact operation | Slow-break, simultaneous | 
| Cable entry | 1 entry tapped for M16 x 1.5 | 
| Cable outer diameter | 7…10 mm | 
| Electrical connection | Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end | 
| Number of poles | 2 | 
| Locking options description | Without locking of actuator | 
| COMPLEMENTARY | |
| Insulation | Double insulated | 
| Positive opening | With NC contact | 
| Mechanical durability | 1000000 cycles | 
| Positive opening minimum force | 15 N | 
| Minimum actuation speed | 0.01 m/s | 
| Maximum actuation speed | 0.5 m/s | 
| [Ie] rated operational current | 
						6 A at 120 V, AC-15, A300 conforming to EN/IEC 60947-5-1 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1  | 
				
| [Ithe] conventional enclosed thermal current | 10 A | 
| [Ui] rated insulation voltage | 
						300 V conforming to UL 508 500 V conforming to EN/IEC 60947-1 300 V conforming to CSA C22.2 No 14  | 
				
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 | 
| Short-circuit protection | 10 A cartridge fuse type gG (gl) | 
| Actuator forcible withdrawal rtc | 10 N | 
| Maximum operating rate | 10 cyc/mn for maximum durability | 
| Safety level | 
						Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508  | 
				
| Safety reliability data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear | 
| Body material | PA (polyamide) | 
| Head material | PA (polyamide) | 
| Depth | 30 mm | 
| Height | 94 mm | 
| Width | 30 mm | 
| Net weight | 0.11 kg | 
| ENVIRONMENT | |
| Standards | 
						EN/ISO 12100 EN 1088/ISO 14119 EN/IEC 60947-5-1 CSA C22.2 No 14 UL 508 EN/IEC 60204-1  | 
				
| Product certifications | 
						CSA UL  | 
				
| Protective treatment | TC | 
| Ambient air temperature for operation | -25…70 °C | 
| Ambient air temperature for storage | -40…70 °C | 
| Vibration resistance | 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 
| Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 | 
| Electrical shock protection class | Class II conforming to EN/IEC 61140 | 
| IP degree of protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |