HCM
XPSUAT13A3AP
Delivery time:2-4 months
	
	
		
				 
			
					Range of product
				 
				
					Harmony Safety Automation
				 
			
				 
			
					Product or component type
				 
				
					Safety module
				 
			
				 
			
					Safety module name
				 
				
					XPSUAT
				 
			
				 
			
					Safety module application
				 
				
					Monitoring antivalent contacts 
			
For emergency stop, guard and light curtain monitoring
Monitoring of pressure-sensitive 4-wire protective devices
				
				 
			
					Function of module
				 
				
					Emergency stop button with 2 NC contacts 
			
Guard monitoring with 1 or 2 limit switches
Monitoring 2 PNP sensors
Magnetic switch monitoring
Light curtain monitoring
RFID switch
Monitoring of electro-sensitive protection equipment (ESPE)
Sensing mat/edges
Proximity sensor monitoring
Monitoring 1 PNP + 1 NPN sensor
				
				 
			
					Safety level
				 
				
					Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1 
			
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
				
				 
			
					Safety reliability data
				 
				
					MTTFd > 30 years conforming to ISO 13849-1 
			
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 0.94E-09 conforming to ISO 13849-1 for SS0
PFHd = 0.95E-09 conforming to ISO 13849-1 for SS1
HFT = 1 conforming to IEC 62061
PFHd = 0.94E-09 conforming to IEC 62061 for SS0
PFHd = 0.95E-09 conforming to IEC 62061 for SS1
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 0.94E-09 conforming to IEC 61508-1 for SS0
PFHd = 0.95E-09 conforming to IEC 61508-1 for SS1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
				
				 
			
					Electrical circuit type
				 
				
					NC pair 
			
PNP pair
Antivalent pair
OSSD pair
				
				 
			
					Connections - terminals
				 
				
					Removable screw terminal block, 0.2...2.5 mm² solid or flexible 
			
Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
				
				 
		
	
					[Us] rated supply voltage
				 
				
					24 V AC - 15...10 % 
			
24 V DC - 20...20 %
				
		
				 
			
					Synchronisation time between inputs
				 
				
					0.5 s 
			
2 s
4 s
				
				 
			
					type of start
				 
				
					Automatic/manual/monitored
				 
			
				 
			
					Power consumption in W
				 
				
					3 W 24 V DC
				 
			
				 
			
					Power consumption in VA
				 
				
					6.5 VA 24 V AC 50/60 Hz
				 
			
				 
			
					Input protection type
				 
				
					Internal, electronic
				 
			
				 
			
					safety outputs
				 
				
					1 NC configurable 
			
3 NO configurable
3 NO immediate
				
				 
			
					safety inputs
				 
				
					2 positive safety input 24 V DC 8 mA 
			
1 negative safety input
				
				 
			
					maximum wire resistance
				 
				
					500 Ohm
				 
			
				 
			
					Time delay range
				 
				
					0...900 s off delay
				 
			
				 
			
					Input compatibility
				 
				
					Normally closed circuit conforming to ISO 14119 
			
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
Antivalent pair conforming to ISO 14119
OSSD pair conforming to IEC 61496-1-2
3-wire proximity sensors PNP
				
				 
			
					[Ie] rated operational current
				 
				
					5 A AC-1 for normally open relay contact 
			
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
3 A AC-1 for normally closed relay contact
1 A AC-15 for normally closed relay contact
3 A DC-1 for normally closed relay contact
1 A DC-13 for normally closed relay contact
				
				 
			
					control outputs
				 
				
					4 on/off configurable pulsed output
				 
			
				 
			
					Input/output type
				 
				
					Semiconductor output 24 V DC, 20 mA Z2, not safety-related 
			
Pulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related
				
				 
			
					[Ith] conventional free air thermal current
				 
				
					16 A
				 
			
				 
			
					Associated fuse rating
				 
				
					10 A gG for NO relay output circuit conforming to IEC 60947-1
				 
			
				 
			
					Minimum output current
				 
				
					20 mA for relay output
				 
			
				 
			
					Minimum output voltage
				 
				
					24 V for relay output
				 
			
				 
			
					Maximum response time on input open
				 
				
					20 ms
				 
			
				 
			
					[Ui] rated insulation voltage
				 
				
					250 V (pollution degree 2) conforming to EN/IEC 60947-1
				 
			
				 
			
					[Uimp] rated impulse withstand voltage
				 
				
					4 kV overvoltage category II conforming to EN/IEC 60947-1
				 
			
				 
			
					Mounting support
				 
				
					35 mm symmetrical DIN rail
				 
			
				 
			
					Depth
				 
				
					120 mm
				 
			
				 
			
					Height
				 
				
					100 mm
				 
			
				 
			
					Width
				 
				
					45 mm
				 
			
				 
		
	
					Net weight
				 
				
					0.350 kg
				 
			
		
				 
			
					Standards
				 
				
					IEC 60947-5-1 
			
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
				
				 
			
					Product certifications
				 
				
					TÜV 
			
cULus
				
				 
			
					IP degree of protection
				 
				
					IP54 (mounting area) conforming to EN/IEC 60947-1 
			
IP40 (housing) conforming to EN/IEC 60947-1
IP20 (terminals) conforming to EN/IEC 60947-1
				
				 
			
					Ambient air temperature for storage
				 
				
					-25…85 °C
				 
			
				 
		
	
					Relative humidity
				 
				
					5…95 % non-condensing