Home » News center » MO496-40 MO496-25 MO496-16
MO496-40 MO496-25 MO496-16
      Promulgator :admin      Time:2016-10-29
Inquiry Photo Description Model Technical parameters Certification Remark
MS116-1.6 Manual Motor Starter 1SAM250000R1006
Rated Operational Power AC-3 (Pe) :
(400V) 0.55 kW
Setting Range :1.00 ... 1.60 A
Trip Class :10A
Rated Operational Current (Ie) :1.60 A
Other models also available, please contact us for details.
MS116-1.0-HKF1-11 Manual Motor Starter 1SAM250005R1005
Rated Operational Power AC-3 (Pe) :
(400V) 0.25 kW
Setting Range :0.63 ... 1.00 A
Trip Class :10A
Rated Operational Current (Ie) :1.00 A
Other models also available, please contact us for details.
MS116-1.0 Manual Motor Starter 1SAM250000R1005
Rated Operational Power AC-3 (Pe) :
(400V) 0.25 kW
Setting Range :0.63 ... 1.00 A
Trip Class :10A
Rated Operational Current (Ie) :1.00 A
Other models also available, please contact us for details.
MS116-0.63-HKF1-11 Manual Motor Starter 1SAM250005R1004
Rated Operational Power AC-3 (Pe) :
(400V) 0.12 kW
Setting Range :0.40 ... 0.63 A
Trip Class :10A
Rated Operational Current (Ie) :0.63 A
Other models also available, please contact us for details.
MS116-0.63 Manual Motor Starter 1SAM250000R1004
Rated Operational Power AC-3 (Pe) :
(400V) 0.12 kW
Setting Range :0.40 ... 0.63 A
Trip Class :10A
Rated Operational Current (Ie) :0.63 A

Other models also available, please contact us for details.
MS116-0.4-HKF1-11 Manual Motor Starter 1SAM250005R1003
Rated Operational Power AC-3 (Pe) :
(400V) 0.09 kW
Setting Range :0.25 ... 0.40 A
Trip Class :10A
Rated Operational Current (Ie) :0.40 A
Other models also available, please contact us for details.
MS116-0.4 Manual Motor Starter 1SAM250000R1003
Rated Operational Power AC-3 (Pe) :
(400V) 0.09 kW
Setting Range :0.25 ... 0.40 A
Trip Class :10A
Rated Operational Current (Ie) :0.40 A
Other models also available, please contact us for details.
MS116-0.25-HKF1-11 Manual Motor Starter 1SAM250005R1002
Rated Operational Power AC-3 (Pe) :
(400V) 0.06 kW
Setting Range :0.16 ... 0.25 A
Trip Class :10A
Rated Operational Current (Ie) :0.25 A

Other models also available, please contact us for details.
MS116-0.25 Manual Motor Starter 1SAM250000R1002
Rated Operational Power AC-3 (Pe) :
(400V) 0.06 kW
Setting Range :0.16 ... 0.25 A
Trip Class :10A
Rated Operational Current (Ie) :0.25 A
Other models also available, please contact us for details.
MS116-0.16-HKF1-11 Manual Motor Starter 1SAM250005R1001
Rated Operational Power AC-3 (Pe) :
(400V) 0.03 kW
Setting Range :0.10 ... 0.16 A
Trip Class :10A
Rated Operational Current (Ie) :0.16 A
Other models also available, please contact us for details.
MS116-0.16 Manual Motor Starter 1SAM250000R1001
Rated Operational Power AC-3 (Pe) :
(400V) 0.03 kW
Setting Range :0.10 ... 0.16 A
Trip Class :10A
Rated Operational Current (Ie) :0.16 A
Other models also available, please contact us for details.
MO496-90 Manual Motor Starter Magnetic Only 1SAM590000R1009
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 70 kA
(500V AC) 10 kA
(690V AC) 10 kA
Rated Operational Current (Ie) :90.0 A
Other models also available, please contact us for details.
MO496-75 Manual Motor Starter Magnetic Only 1SAM590000R1008
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 70 kA
(500V AC) 10 kA
(690V AC) 10 kA
Rated Operational Current (Ie) :75.0 A
Other models also available, please contact us for details.
MO496-63 Manual Motor Starter Magnetic Only 1SAM590000R1007
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 70 kA
(500V AC) 15 kA
(690V AC) 7.5 kA
Rated Operational Current (Ie) :63.0 A
Other models also available, please contact us for details.
MO496-50 Manual Motor Starter Magnetic Only 1SAM590000R1006
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 100 kA
(500V AC) 15 kA
(690V AC) 10 kA
Rated Operational Current (Ie) :50.0 A
Other models also available, please contact us for details.
MO496-40 Manual Motor Starter Magnetic Only 1SAM590000R1005
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 100 kA
(500V AC) 18 kA
(690V AC) 12 kA
Rated Operational Current (Ie) :40.0 A
Other models also available, please contact us for details.
MO496-32 Manual Motor Starter Magnetic Only 1SAM590000R1004
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 100 kA
(500V AC) 22 kA
(690V AC) 12 kA
Rated Operational Current (Ie) :32.0 A
Other models also available, please contact us for details.
MO496-25 Manual Motor Starter Magnetic Only 1SAM590000R1003
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 100 kA
(500V AC) 30 kA
(690V AC) 12 kA
Rated Operational Current (Ie) :25.0 A
Other models also available, please contact us for details.
MO496-20 Manual Motor Starter Magnetic Only 1SAM590000R1002
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 100 kA
(500V AC) 30 kA
(690V AC) 12 kA
Rated Operational Current (Ie) :20.0 A
Other models also available, please contact us for details.
MO496-16 Manual Motor Starter Magnetic Only 1SAM590000R1001
Rated Ultimate Short-Circuit Breaking Capacity (Icu) :
(230V AC) 100 kA
(400V AC) 100 kA
(440V AC) 100 kA
(500V AC) 30 kA
(690V AC) 12 kA
Rated Operational Current (Ie) :16.0 A
Other models also available, please contact us for details.
 
No comment