MS116-32-HKF1-11
      Promulgator :admin      Time:2016-10-29
Inquiry Photo Description Model Technical parameters Certification Remark
MS132-0.16 Manual Motor Starter 1SAM350000R1001
Rated Operational Power AC-3 (Pe) :
(400V) 0.03 kW
Setting Range :0.10 ... 0.16 A
Trip Class :10A
Rated Operational Current (Ie) :0.16 A
Other models also available, please contact us for details.
MS116-6.3-HKF1-11 Manual Motor Starter 1SAM250005R1009
Rated Operational Power AC-3 (Pe) :
(400V) 2.2 kW
Setting Range :4.00 ... 6.30 A
Trip Class :10A
Rated Operational Current (Ie) :6.30 A
Other models also available, please contact us for details.
MS116-6.3 Manual Motor Starter 1SAM250000R1009
Rated Operational Power AC-3 (Pe) :
(400V) 2.2 kW
Setting Range :4.00 ... 6.30 A
Trip Class :10A
Rated Operational Current (Ie) :6.30 A
Other models also available, please contact us for details.
MS116-4.0-HKF1-11 Manual Motor Starter 1SAM250005R1008
Rated Operational Power AC-3 (Pe) :
(400V) 1.5 kW
Setting Range :2.50 ... 4.00 A
Trip Class :10A
Rated Operational Current (Ie) :4.00 A

Other models also available, please contact us for details.
MS116-4.0 Manual Motor Starter 1SAM250000R1008
Rated Operational Power AC-3 (Pe) :
(400V) 1.5 kW
Setting Range :2.50 ... 4.00 A
Trip Class :10A
Rated Operational Current (Ie) :4.00 A
Other models also available, please contact us for details.
MS116-32-HKF1-11 Manual Motor Starter 1SAM250005R1015
Rated Operational Power AC-3 (Pe) :
(400V) 15 kW
Setting Range :25.0 ... 32.0 A
Trip Class :10A
Rated Operational Current (Ie) :32.0 A
Other models also available, please contact us for details.
MS116-32 Manual Motor Starter 1SAM250000R1015
Rated Operational Power AC-3 (Pe) :
(400V) 15 kW
Setting Range :25.0 ... 32.0 A
Trip Class :10A
Rated Operational Current (Ie) :32.0 A

Other models also available, please contact us for details.
MS116-25-HKF1-11 Manual Motor Starter 1SAM250005R1014
Rated Operational Power AC-3 (Pe) :
(400V) 11 kW
Setting Range :20.0 ... 25.0 A
Trip Class :10A
Rated Operational Current (Ie) :25.0 A
Other models also available, please contact us for details.
MS116-25 Manual Motor Starter 1SAM250000R1014
Rated Operational Power AC-3 (Pe) :
(400V) 11 kW
Setting Range :20.0 ... 25.0 A
Trip Class :10A
Rated Operational Current (Ie) :25.0 A
Other models also available, please contact us for details.
MS116-20-HKF1-11 Manual Motor Starter 1SAM250005R1013
Rated Operational Power AC-3 (Pe) :
(400V) 9.0 kW
Setting Range :16.0 ... 20.0 A
Trip Class :10A
Rated Operational Current (Ie) :20.0 A
Other models also available, please contact us for details.
MS116-20 Manual Motor Starter 1SAM250000R1013
Rated Operational Power AC-3 (Pe) :
(400V) 9.0 kW
Setting Range :16.0 ... 20.0 A
Trip Class :10A
Rated Operational Current (Ie) :20.0 A

Other models also available, please contact us for details.
MS116-2.5-HKF1-11 Manual Motor Starter 1SAM250005R1007
Rated Operational Power AC-3 (Pe) :
(400V) 0.75 kW
Setting Range :1.60 ... 2.50 A
Trip Class :10A
Rated Operational Current (Ie) :2.50 A
Other models also available, please contact us for details.
MS116-2.5 Manual Motor Starter 1SAM250000R1007
Rated Operational Power AC-3 (Pe) :
(400V) 0.75 kW
Setting Range :1.60 ... 2.50 A
Trip Class :10A
Rated Operational Current (Ie) :2.50 A
Other models also available, please contact us for details.
MS116-16-HKF1-11 Manual Motor Starter 1SAM250005R1011
Rated Operational Power AC-3 (Pe) :
(400V) 7.5 kW
Setting Range :10.0 ... 16.0 A
Trip Class :10A
Rated Operational Current (Ie) :16.0 A
Other models also available, please contact us for details.
MS116-16 Manual Motor Starter 1SAM250000R1011
Rated Operational Power AC-3 (Pe) :
(400V) 7.5 kW
Setting Range :10.0 ... 16.0 A
Trip Class :10A
Rated Operational Current (Ie) :16.0 A
Other models also available, please contact us for details.
MS116-12-HKF1-11 Manual Motor Starter 1SAM250005R1012
Rated Operational Power AC-3 (Pe) :
(400V) 5.5 kW
Setting Range :8.00 ... 12.0 A
Trip Class :10A
Rated Operational Current (Ie) :12.0 A
Other models also available, please contact us for details.
MS116-12 Manual Motor Starter 1SAM250000R1012
Rated Operational Power AC-3 (Pe) :
(400V) 5.5 kW
Setting Range :8.00 ... 12.0 A
Trip Class :10A
Rated Operational Current (Ie) :12.0 A
Other models also available, please contact us for details.
MS116-10-HKF1-11 Manual Motor Starter 1SAM250005R1010
Rated Operational Power AC-3 (Pe) :
(400V) 4.0 kW
Setting Range :6.30 ... 10.0 A
Trip Class :10A
Rated Operational Current (Ie) :10.0 A
Other models also available, please contact us for details.
MS116-10 Manual Motor Starter 1SAM250000R1010
Rated Operational Power AC-3 (Pe) :
(400V) 4.0 kW
Setting Range :6.30 ... 10.0 A
Trip Class :10A
Rated Operational Current (Ie) :10.0 A
Other models also available, please contact us for details.
MS116-1.6-HKF1-11 Manual Motor Starter 1SAM250005R1006
Rated Operational Power AC-3 (Pe) :
(400V) 0.55 kW
Setting Range :1.00 ... 1.60 A
Trip Class :10A
Rated Operational Current (Ie) :1.60 A

Other models also available, please contact us for details.
 