HCM
ZB5-AZ102
Delivery time:in stock
	
	
		Specifications
	
| Range of product | Harmony XB5 | 
|---|---|
| Product or component type | Complete body/contact assembly | 
| Device short name | ZB5 | 
| Fixing collar material | Plastic | 
| Sale per indivisible quantity | 1 | 
| Head type | Standard | 
| Contacts type and composition | 1 NC | 
| Contact operation | Slow-break | 
| Contact block type | Single | 
| Connections - terminals | 
								Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1  | 
						
| CAD overall width | 30 mm | 
|---|---|
| CAD overall height | 42 mm | 
| CAD overall depth | 32 mm | 
| Terminals description ISO n°1 | (11-12)NC | 
| Net weight | 0.021 kg | 
| Device composition | 
								Body Fixing collar  | 
						
| Contacts usage | Standard contacts | 
| Positive opening | With conforming to EN/IEC 60947-5-1 appendix K | 
| Operating travel | 
								1.5 mm (NC changing electrical state) 4.3 mm (total travel)  | 
						
| Operating force | 2 N NC changing electrical state | 
| Mechanical durability | 10000000 cycles | 
| Tightening torque | 0.8…1.2 N.m conforming to EN 60947-1 | 
| Shape of screw head | 
								Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver  | 
						
| Contacts material | Silver alloy (Ag/Ni) | 
| Short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | 
| [Ith] conventional free air thermal current | 10 A conforming to EN/IEC 60947-5-1 | 
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to EN 60947-1 | 
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-1 | 
| [Ie] rated operational current | 
								3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1  | 
						
| Electrical durability | 
								1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C  | 
						
| Electrical reliability | 
								Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4  | 
						
| device presentation | Basic sub-assemblies | 
| Protective treatment | TH | 
|---|---|
| Ambient air temperature for storage | -40…70 °C | 
| Ambient air temperature for operation | -40…70 °C | 
| IP degree of protection | IP20 conforming to IEC 60529 | 
| Standards | 
								UL 508 EN/IEC 60947-5-1 JIS C8201-5-1 EN/IEC 60947-1 CSA C22.2 No 14 EN/IEC 60947-5-4 JIS C8201-1  | 
						
| Product certifications | 
								CSA UL GL LROS (Lloyds register of shipping) BV DNV  | 
						
| Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 | 
| Shock resistance | 
								30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27  | 
						