Technical data

Power contactor, AC-3 65 A, 30 kW / 400 V 1 NO + 1 NC, 230 V AC 50/60 Hz, 3-pole Size S2, screw terminals
product brand name SIRIUS
product designation Power contactor
product type designation 3RT2
General technical data
size of contactor S2
product extension
● function module for communication No
● auxiliary switch Yes
power loss [W] for rated value of the current
● at AC in hot operating state 11.4 W
● at AC in hot operating state per pole 3.8 W
● without load current share typical 17.2 W
insulation voltage
● of main circuit with degree of pollution 3 rated value 690 V
● of auxiliary circuit with degree of pollution 3 rated value 690 V
surge voltage resistance
● of main circuit rated value 6 kV
● of auxiliary circuit rated value 6 kV
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 400 V
shock resistance at rectangular impulse
● at AC 11.8g / 5 ms, 7.4g / 10 ms
shock resistance with sine pulse
● at AC 18.5g / 5 ms, 11.6g / 10 ms
mechanical service life (switching cycles)
● of contactor typical 10 000 000
● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000
● of the contactor with added auxiliary switch block typical 10 000 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (Date) 10/01/2014
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -25 ... +60 °C
● during storage -55 ... +80 °C
relative humidity minimum 10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 %
Main circuit
number of poles for main current circuit 3
number of NO contacts for main contacts 3
operating voltage
● at AC-3 rated value maximum 690 V
● at AC-3e rated value maximum 690 V
operational current
● at AC-1 at 400 V at ambient temperature 40 °C rated value 80 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value 80 A
— up to 690 V at ambient temperature 60 °C rated value 70 A
● at AC-3
— at 400 V rated value 65 A
— at 500 V rated value 65 A
— at 690 V rated value 47 A
● at AC-3e
— at 400 V rated value 65 A
— at 500 V rated value 65 A
— at 690 V rated value 47 A
● at AC-4 at 400 V rated value 55 A
● at AC-5a up to 690 V rated value 70.4 A
● at AC-5b up to 400 V rated value 53.9 A
● at AC-6a
— up to 230 V for current peak value n=20 rated value 56.9 A
— up to 400 V for current peak value n=20 rated value 56.9 A
— up to 500 V for current peak value n=20 rated value 56.9 A
— up to 690 V for current peak value n=20 rated value 47 A
● at AC-6a
— up to 230 V for current peak value n=30 rated value 38 A
— up to 400 V for current peak value n=30 rated value 38 A
— up to 500 V for current peak value n=30 rated value 38 A
— up to 690 V for current peak value n=30 rated value 38 A
minimum cross-section in main circuit at maximum AC-1 rated value 25 mm²
operational current for approx. 200000 operating cycles at AC-4
● at 400 V rated value 28 A
● at 690 V rated value 22 A
operational current
● at 1 current path at DC-1
— at 24 V rated value 55 A
— at 110 V rated value 4.5 A
— at 220 V rated value 1 A
— at 440 V rated value 0.4 A
— at 600 V rated value 0.25 A
● with 2 current paths in series at DC-1
— at 24 V rated value 55 A
— at 110 V rated value 45 A
— at 220 V rated value 5 A
— at 440 V rated value 1 A
— at 600 V rated value 0.8 A
● with 3 current paths in series at DC-1
— at 24 V rated value 55 A
— at 110 V rated value 55 A
— at 220 V rated value 45 A
— at 440 V rated value 2.9 A
— at 600 V rated value 1.4 A
● at 1 current path at DC-3 at DC-5
— at 24 V rated value 35 A
— at 110 V rated value 2.5 A
— at 220 V rated value 1 A
— at 440 V rated value 0.1 A
— at 600 V rated value 0.06 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value 55 A
— at 110 V rated value 25 A
— at 220 V rated value 5 A
— at 440 V rated value 0.27 A
— at 600 V rated value 0.16 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value 55 A
— at 110 V rated value 55 A
— at 220 V rated value 25 A
— at 440 V rated value 0.6 A
— at 600 V rated value 0.35 A
operating power
● at AC-2 at 400 V rated value 30 kW
● at AC-3
— at 230 V rated value 18.5 kW
— at 400 V rated value 30 kW
— at 500 V rated value 37 kW
— at 690 V rated value 37 kW
● at AC-3e
— at 230 V rated value 18.5 kW
— at 400 V rated value 30 kW
— at 500 V rated value 37 kW
— at 690 V rated value 37 kW
operating power for approx. 200000 operating cycles at AC-4
● at 400 V rated value 14.7 kW
● at 690 V rated value 20 kW
operating apparent power at AC-6a
● up to 230 V for current peak value n=20 rated value 22.6 kVA
● up to 400 V for current peak value n=20 rated value 39.4 kVA
● up to 500 V for current peak value n=20 rated value 49.2 kVA
● up to 690 V for current peak value n=20 rated value 56.1 kVA
operating apparent power at AC-6a
● up to 230 V for current peak value n=30 rated value 15.1 kVA
● up to 400 V for current peak value n=30 rated value 26.2 kVA
● up to 500 V for current peak value n=30 rated value 32.8 kVA
● up to 690 V for current peak value n=30 rated value 45.3 kVA
short-time withstand current in cold operating state up to 40 °C
● limited to 1 s switching at zero current maximum 1 055 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum 730 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum 520 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum 336 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum 272 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency
● at AC 5 000 1/h
operating frequency
● at AC-1 maximum 800 1/h
● at AC-2 maximum 400 1/h
● at AC-3 maximum 700 1/h
● at AC-3e maximum 700 1/h
● at AC-4 maximum 200 1/h
Control circuit/ Control
type of voltage of the control supply voltage AC
control supply voltage at AC
● at 50 Hz rated value 230 V
● at 60 Hz rated value 230 V
operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz 0.8 ... 1.1
● at 60 Hz 0.85 ... 1.1
apparent pick-up power of magnet coil at AC
● at 50 Hz 210 VA
● at 60 Hz 188 VA
inductive power factor with closing power of the coil
● at 50 Hz 0.69
● at 60 Hz 0.65
apparent holding power of magnet coil at AC
● at 50 Hz 17.2 VA
● at 60 Hz 16.5 VA
inductive power factor with the holding power of the coil
● at 50 Hz 0.36
● at 60 Hz 0.39
closing delay
● at AC 10 ... 80 ms
opening delay
● at AC 10 ... 18 ms
arcing time 10 ... 20 ms
control version of the switch operating mechanism Standard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact 1
number of NO contacts for auxiliary contacts instantaneous contact 1
operational current at AC-12 maximum 10 A
operational current at AC-15
● at 230 V rated value 10 A
● at 400 V rated value 3 A
● at 500 V rated value 2 A
● at 690 V rated value 1 A
operational current at DC-12
● at 24 V rated value 10 A
● at 48 V rated value 6 A
● at 60 V rated value 6 A
● at 110 V rated value 3 A
● at 125 V rated value 2 A
● at 220 V rated value 1 A
● at 600 V rated value 0.15 A
operational current at DC-13
● at 24 V rated value 10 A
● at 48 V rated value 2 A
● at 60 V rated value 2 A
● at 110 V rated value 1 A
● at 125 V rated value 0.9 A
● at 220 V rated value 0.3 A
● at 600 V rated value 0.1 A
contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value 65 A
● at 600 V rated value 52 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value 5 hp
— at 230 V rated value 10 hp
● for 3-phase AC motor
— at 200/208 V rated value 20 hp
— at 220/230 V rated value 20 hp
— at 460/480 V rated value 50 hp
— at 575/600 V rated value 50 hp
contact rating of auxiliary contacts according to UL A600 / P600
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
— with type of assignment 2 required gG: 125A (690V,100kA), aM: 63A (690V,100kA), BS88: 100A (415V,80kA)
● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
● side-by-side mounting Yes
height 114 mm
width 55 mm
depth 130 mm
required spacing
● with side-by-side mounting
— forwards 10 mm
— upwards 10 mm
— downwards 10 mm
— at the side 0 mm
● for grounded parts
— forwards 10 mm
— upwards 10 mm
— at the side 6 mm
— downwards 10 mm
● for live parts
— forwards 10 mm
— upwards 10 mm
— downwards 10 mm
— at the side 6 mm
Connections/ Terminals
type of electrical connection
● for main current circuit screw-type terminals
● for auxiliary and control circuit screw-type terminals
● at contactor for auxiliary contacts Screw-type terminals
● of magnet coil Screw-type terminals
type of connectable conductor cross-sections
● for main contacts
— solid or stranded 2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
— finely stranded with core end processing 2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
● at AWG cables for main contacts 2x (18 ... 2), 1x (18 ... 1)
connectable conductor cross-section for main contacts
● finely stranded with core end processing 1 ... 35 mm²
connectable conductor cross-section for auxiliary contacts
● solid or stranded 0.5 ... 2.5 mm²
● finely stranded with core end processing 0.5 ... 2.5 mm²
type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14)
AWG number as coded connectable conductor cross section
● for main contacts 18 ... 1
● for auxiliary contacts 20 ... 14
Safety related data
product function
● mirror contact according to IEC 60947-4-1 Yes
● positively driven operation according to IEC 60947-5-1 No
B10 value with high demand rate according to SN 31920 1 000 000
proportion of dangerous failures
● with low demand rate according to SN 31920 40 %
● with high demand rate according to SN 31920 73 %
failure rate [FIT] with low demand rate according to SN 31920 100 FIT
protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front
suitability for use
● safety-related switching OFF Yes
Certificates/ approvals

Downloads and manuals

General Product Approval

CSA

CCC

Confirmation

UL

KC

EAC

EMC Functional Safety/Safety of Machinery Declaration of Conformity Test Certificates

RCM

Type Examination Certificate

EC/EU-Declaration of Conformity

UK Declaration of Conformity

Type Test Certificates/Test Report

Special Test Certificate

Marine / Shipping

ABS (American Bureau of Shipping)

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

RINA / Registro Italiano Navale

Marine / Shipping other Railway Dangerous Good

RMRS / Russian Maritime Register

Confirmation

Confirmation

Vibration and Shock

Transport Information

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified: 2/15/2022
Date
5/2/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number) 3RT2037-1AL20
Product Description Power contactor, AC-3 65 A, 30 kW / 400 V 1 NO + 1 NC, 230 V AC 50/60 Hz, 3-pole Size S2, screw terminals
Product family SIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM) PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group 41B / 41B
Surcharge for Raw Materials None
Metal Factor LFO-----
Delivery information
Export Control Regulations AL : N / ECCN : N
Standard lead time ex-works 50 Day/Days
Net Weight (kg) 1,049 Kg
Packaging Dimension 62,00 x 122,50 x 142,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN 4011209940307
UPC 887621917296
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5338
Group Code R711
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.10.2014
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
Version Classification
eClass 6 27-37-10-03
eClass 7.1 27-37-10-03
eClass 8 27-37-10-03
eClass 9 27-37-10-03
eClass 9.1 27-37-10-03
ETIM 5 EC000066
ETIM 6 EC000066
ETIM 7 EC000066
ETIM 8 EC000066
IDEA 4 4755
UNSPSC 15 39-12-15-29

ETIM data

ETIM: EC000066 - Power contactor, AC switching

Value Unit
Rated operation power at AC-4, 400 V (EF008496) - kW
Rated control supply voltage Us at DC (EF003980) ['-', '-'] V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 80 A
Rated operation current Ie at AC-3, 400 V (EF001392) 65 A
Rated operation power at AC-3, 400 V (EF001364) 30.0 kW
Rated operation current Ie at AC-4, 400 V (EF008495) 55 A
Rated operation power NEMA (EF011960) 36.7749375 kW
Modular version (EF001126) true
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) -
Number of main contacts as normally open contact (EF001374) 3
Rated control supply voltage Us at AC 50HZ (EF003978) - V
Rated control supply voltage Us at AC 60HZ (EF003979) - V

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$66.50
$275.50
$49.00
$11.00
$86.00
$39.00
$1413.10
$21.00
$28.50
Business time
9:00-22:00
  • Email:support@rig123.com