HCM(HJY)
LUB12
Delivery time:in stock
	
	
		
				 
			
					Range
				 
				
					TeSys
				 
			
				 
			
					Product name
				 
				
					TeSys Ultra
				 
			
				 
			
					Device short name
				 
				
					LUB
				 
			
				 
			
					Product or component type
				 
				
					Non reversing power base
				 
			
				 
			
					Device application
				 
				
					Motor control 
			
Motor protection
				
				 
			
					Poles description
				 
				
					3P
				 
			
				 
			
					Suitability for isolation
				 
				
					Yes
				 
			
				 
			
					[Ue] rated operational voltage
				 
				
					690 V AC for power circuit
				 
			
				 
			
					Network frequency
				 
				
					40...60 Hz
				 
			
				 
			
					[Ith] conventional free air thermal current
				 
				
					12 A
				 
			
				 
			
					[Ie] rated operational current
				 
				
					12 A at <= 440 V 
			
12 A at 500 V
9 A at 690 V
				
				 
			
					Utilisation category
				 
				
					AC-43 
			
AC-44
AC-41
				
				 
			
					[Ics] rated service breaking capacity
				 
				
					50 kA at 230 V 
			
50 kA at 440 V
10 kA at 500 V
4 kA at 690 V
				
				 
			
					Auxiliary contact composition
				 
				
					1 NO + 1 NC
				 
			
				 
			
					Auxiliary contacts type
				 
				
					Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 
			
type mirror contact (1 NC) conforming to IEC 60947-1
				
				 
		
	
					[Uc] control circuit voltage
				 
				
					24 V AC 50/60 Hz 
			
24 V DC
48...72 V AC 50/60 Hz
48...72 V DC
110...240 V AC 50/60 Hz
110...220 V DC
				
		
				 
			
					Typical current consumption
				 
				
					130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 
			
140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
150 mA at 24 V DC I maximum while closing with LUCM
280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA at 24 V DC I rms sealed with LUCM
				
				 
			
					Heat dissipation
				 
				
					2 W for control circuit with LUCA, LUCB, LUCC, LUCD 
			
1.7 W for control circuit with LUCM
				
				 
			
					Safety reliability level
				 
				
					B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 
			
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
				
				 
			
					Operating time
				 
				
					35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit 
			
50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
75 ms closing with LUCM for control circuit
				
				 
			
					Mechanical durability
				 
				
					15 Mcycles
				 
			
				 
			
					Maximum operating rate
				 
				
					3600 cyc/h
				 
			
				 
			
					Product certifications
				 
				
					CE 
			
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
				
				 
			
					Standards
				 
				
					EN 60947-6-2 
			
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
				
				 
			
					[Ui] rated insulation voltage
				 
				
					690 V conforming to IEC 60947-6-2 (pollution degree 3) 
			
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
				
				 
			
					[Uimp] rated impulse withstand voltage
				 
				
					6 kV conforming to IEC 60947-6-2
				 
			
				 
			
					Safe separation of circuit
				 
				
					400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 
			
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
				
				 
			
					Fixing mode
				 
				
					Clipped (DIN rail) 
			
Screw-fixed (plate)
				
				 
			
					Connections - terminals
				 
				
					Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end 
			
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid
Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
				
				 
			
					Tightening torque
				 
				
					Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm 
			
Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm
Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm
Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
				
				 
			
					Width
				 
				
					45 mm
				 
			
				 
			
					Height
				 
				
					154 mm
				 
			
				 
			
					Depth
				 
				
					126 mm
				 
			
				 
			
					Net weight
				 
				
					0.9 kg
				 
			
				 
		
	
					Compatibility code
				 
				
					LUB
				 
			
		
				 
			
					IP degree of protection
				 
				
					IP20 conforming to IEC 60947-1 (front panel and wired terminals) 
			
IP20 conforming to IEC 60947-1 (other faces)
IP40 conforming to IEC 60947-1 (front panel outside connection zone)
				
				 
			
					Protective treatment
				 
				
					TH conforming to IEC 60068
				 
			
				 
			
					Ambient air temperature for operation
				 
				
					-25…60 °C with LUCM 
			
-25…70 °C with LUCA, LUCB, LUCC, LUCD
				
				 
			
					Ambient air temperature for storage
				 
				
					-40…85 °C
				 
			
				 
			
					Fire resistance
				 
				
					960 °C parts supporting live components conforming to IEC 60695-2-12 
			
650 °C conforming to IEC 60695-2-12
				
				 
			
					Operating altitude
				 
				
					2000 m
				 
			
				 
			
					Shock resistance
				 
				
					10 gn power poles open conforming to IEC 60068-2-27 
			
15 gn power poles closed conforming to IEC 60068-2-27
				
				 
			
					Vibration resistance
				 
				
					2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27 
			
4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
				
				 
			
					Resistance to electrostatic discharge
				 
				
					8 kV level 3 in open air conforming to IEC 61000-4-2 
			
8 kV level 4 on contact conforming to IEC 61000-4-2
				
				 
			
					Resistance to radiated fields
				 
				
					10 V/m 3 conforming to IEC 61000-4-3
				 
			
				 
			
					Resistance to fast transients
				 
				
					2 kV class 3 serial link conforming to IEC 61000-4-4 
			
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
				
				 
			
					Non-dissipating shock wave
				 
				
					1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2 
			
1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2
2 kV common mode 24...240 V AC conforming to IEC 60947-6-2
2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
				
				 
			
					Immunity to radioelectric fields
				 
				
					10 V conforming to IEC 61000-4-6
				 
			
				 
			
					Immunity to microbreaks
				 
				
					3 ms for control circuit
				 
			
				 
		
	
					Immunity to voltage dips
				 
				
					70 % / 500 ms conforming to IEC 61000-4-11