HCM(YL)
XCSE5312
Delivery time:6 weeks
	
| MAIN | |
|---|---|
| Range of product | Telemecanique Safety switches XCS | 
| Product or component type | Safety switch | 
| Component name | XCSE | 
| Design | Rectangular | 
| Material | Metal | 
| Head type | Key operated turret head | 
| Contacts type and composition | 1 NC + 2 NO | 
| Contact operation | Slow-break, break before make | 
| Solenoid contacts type and composition | 1 NC + 1 NO (slow-break, simultaneous) | 
| Cable entry | 2 entries tapped for M20 x 1.5 | 
| Electromagnet interlocking | Locking on de-energisation and unlocking on energisation of solenoid | 
| [Us] rated supply voltage | 24 V - 20...10 % | 
| Cable outer diameter | 7…13 mm | 
| Electrical connection | Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end | 
| Number of poles | 3 | 
| Locking options description | With interlocking, locking by solenoid | 
| Local signalling | 2 LEDs (green or orange) for guard open/guard closed and locked | 
| Signalling circuit voltage | 24/48 V (voltage limits: 20...52 V) | 
| COMPLEMENTARY | |
| Positive opening | With NC contact | 
| Supply voltage type | AC/DC | 
| Supply frequency | 50/60 Hz | 
| Load factor | 1 | 
| Power consumption in VA | 
						10 VA inrush 10 VA sealed  | 
				
| Signalling circuit type | AC/DC | 
| Signalling circuit consumption | 7 mA | 
| Mechanical durability | 1000000 cycles | 
| Minimum actuation speed | 0.01 m/s | 
| Maximum actuation speed | 0.5 m/s | 
| [Ie] rated operational current | 
						0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1  | 
				
| [Ithe] conventional enclosed thermal current | 6 A | 
| [Ui] rated insulation voltage | 50 V conforming to EN/IEC 60947-1 for signalling circuit | 
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 | 
| Protection type | Overvoltage protection for signalling circuit | 
| Short-circuit protection | 10 A cartridge fuse type gG (gl) | 
| Actuator forcible withdrawal rtc | 2000 N | 
| Minimum actuator force for extraction | 20 N | 
| Maximum operating rate | 10 cyc/mn for maximum durability | 
| Safety level | 
						Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508  | 
				
| Safety reliability data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear | 
| Body material | Zamak | 
| Head material | Zamak | 
| Depth | 44 mm | 
| Height | 146 mm | 
| Width | 98 mm | 
| Net weight | 1.14 kg | 
| ENVIRONMENT | |
| Standards | 
						UL 508 EN/ISO 12100 CSA C22.2 No 14 EN/IEC 60947-5-1 EN 1088/ISO 14119 EN/IEC 60204-1  | 
				
| Product certifications | 
						UL CSA  | 
				
| Protective treatment | TC | 
| Ambient air temperature for operation | -25…40 °C | 
| Ambient air temperature for storage | -40…70 °C | 
| Vibration resistance | 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 
| Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 | 
| Electrical shock protection class | Class I conforming to EN/IEC 61140 | 
| IP degree of protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |