ZLL(XWY)
PLS6-C4/2-DC
delivery time:in stock
RATED OPERATIONAL CURRENT FOR SPECIFIED HEAT DISSIPATION (IN)
10.11 SHORT-CIRCUIT RATING
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.4 CLEARANCES AND CREEPAGE DISTANCES
Meets the product standard's requirements.
RATED SHORT-CIRCUIT BREAKING CAPACITY (EN 60898) AT 230 V
10.12 ELECTROMAGNETIC COMPATIBILITY
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
RATED SHORT-CIRCUIT BREAKING CAPACITY (EN 60898) AT 400 V
10.2.5 LIFTING
Does not apply, since the entire switchgear needs to be evaluated.
10.2.3.1 VERIFICATION OF THERMAL STABILITY OF ENCLOSURES
Meets the product standard's requirements.
10.8 CONNECTIONS FOR EXTERNAL CONDUCTORS
Is the panel builder's responsibility.
RATED SHORT-CIRCUIT BREAKING CAPACITY (IEC 60947-2) AT 400 V
RATED SHORT-CIRCUIT BREAKING CAPACITY (IEC 60947-2) AT 230 V
SPECIAL FEATURES
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
AMBIENT OPERATING TEMPERATURE - MAX
HEAT DISSIPATION PER POLE, CURRENT-DEPENDENT
FEATURES
Additional equipment possible
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) - MIN
10.9.3 IMPULSE WITHSTAND VOLTAGE
Is the panel builder's responsibility.
AMBIENT OPERATING TEMPERATURE - MIN
10.6 INCORPORATION OF SWITCHING DEVICES AND COMPONENTS
Does not apply, since the entire switchgear needs to be evaluated.
10.5 PROTECTION AGAINST ELECTRIC SHOCK
Does not apply, since the entire switchgear needs to be evaluated.
USED WITH
Miniature circuit breaker
PLS6
EQUIPMENT HEAT DISSIPATION, CURRENT-DEPENDENT
10.13 MECHANICAL FUNCTION
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 MECHANICAL IMPACT
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 TESTING OF ENCLOSURES MADE OF INSULATING MATERIAL
Is the panel builder's responsibility.
STATIC HEAT DISSIPATION, NON-CURRENT-DEPENDENT
APPLICATION
Switchgear for DC applications
10.3 DEGREE OF PROTECTION OF ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
NUMBER OF POLES (PROTECTED)
HEAT DISSIPATION CAPACITY
WIDTH IN NUMBER OF MODULAR SPACINGS
10.2.3.2 VERIFICATION OF RESISTANCE OF INSULATING MATERIALS TO NORMAL HEAT
Meets the product standard's requirements.
10.2.3.3 RESIST. OF INSUL. MAT. TO ABNORMAL HEAT/FIRE BY INTERNAL ELECT. EFFECTS
Meets the product standard's requirements.
10.9.2 POWER-FREQUENCY ELECTRIC STRENGTH
Is the panel builder's responsibility.
CONNECTABLE CONDUCTOR CROSS SECTION (SOLID-CORE) - MAX
10.7 INTERNAL ELECTRICAL CIRCUITS AND CONNECTIONS
Is the panel builder's responsibility.
CONNECTABLE CONDUCTOR CROSS SECTION (MULTI-WIRED) - MIN
RATED IMPULSE WITHSTAND VOLTAGE (UIMP)
10.10 TEMPERATURE RISE
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
RATED SWITCHING CAPACITY (IEC/EN 60947-2)
CONNECTABLE CONDUCTOR CROSS SECTION (MULTI-WIRED) - MAX
TYPE
Miniature circuit breaker
PLS6
10.2.2 CORROSION RESISTANCE
Meets the product standard's requirements.
10.2.4 RESISTANCE TO ULTRA-VIOLET (UV) RADIATION
Meets the product standard's requirements.
10.2.7 INSCRIPTIONS
Meets the product standard's requirements.
RATED OPERATIONAL VOLTAGE (UE) - MAX
RATED INSULATION VOLTAGE (UI)