HCM
NBN15-30GM60-I3-5M
Delivery time:4 days
| General specifications | ||
|---|---|---|
| Output type | Analog current output | |
| Installation | non-flush | |
| Output polarity | DC | |
| Measurement range | 5 ... 15 mm | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 15 ... 30 V DC | |
| Repeat accuracy | 0 ... 200 µm | |
| No-load supply current | ≤ 12 mA | |
| Analog output | ||
| Output type | 0 ... 20 mA | |
| Slope of output characteristic | 2 mA / mm | |
| Linearity error | ≤ ± 5 % of full-scale value | |
| Load resistor | ≤ 500 Ω | |
| Rate of current rise | ||
| 0 ... 20 mA | ≤ 17.5 A/s | |
| 20 ... 0 mA | ≤ 16.4 A/s | |
| Temperature drift | ≤ ± 0.15 %/K of the measured value | |
| Residual ripple | ± 125 µA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards |
EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
|
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross section | 0.75 mm2 | |
| Housing material | Stainless steel V2A | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Cable diameter | 6.4 mm ± 0.2 mm | |
| Bending radius | > 10 x cable diameter | |