Schneider TeSys D contactor LC1D95E7
1
  • Schneider TeSys D contactor LC1D95E7
2
views: 3899

Schneider TeSys D contactor LC1D95E7

Rate:
0.0000/5

( 0 reviews )

Item NO.: V020962 MOQ: 0
Weight:    1.61kgs
Package Size:  
 Price:
$180.00
 Qty:
      $180.00
 Shipping:   Calculate Shipping Cost

Schneider TeSys D contactor LC1D95E7

in stock

Product data sheet

Characteristics
LC1D95E7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V
95 A - 48 V AC 50/60 Hz coil
Main
Range TeSys
Product name TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-4
AC-1
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage <= 300 V DC 25...400 Hz for power circuit
<= 1000 V AC for power circuit
[Ie] rated operational current 125 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
95 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
Motor power kW 45 kW at 660...690 V AC 50/60 Hz AC-3
45 kW at 415...440 V AC 50/60 Hz AC-3
55 kW at 500 V AC 50/60 Hz AC-3
45 kW at 1000 V AC 50/60 Hz AC-3
15 kW at 400 V AC 50/60 Hz AC-4
25 kW at 220...230 V AC 50/60 Hz AC-3
45 kW at 380...400 V AC 50/60 Hz AC-3
Motor power HP (UL / CSA) 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
25 hp at 230/240 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 48 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage Conforming to IEC 60947
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Aug 9, 2019
1
Overvoltage category III
[Ith] conventional free air thermal
current
125 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
Irms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A <= 40 °C 1 s power circuit
135 A <= 40 °C 10 min power circuit
400 A <= 40 °C 1 min power circuit
800 A <= 40 °C 10 s power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Associated fuse rating 160 A gG at <= 690 V coordination type 2 for power circuit
200 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Average impedance 0.8 mOhm at 50 Hz - Ith 125 A for power circuit
[Ui] rated insulation voltage 1000 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
Electrical durability 1.2 Mcycles 95 A AC-3 at Ue <= 440 V
1.3 Mcycles 125 A AC-1 at Ue <= 440 V
Power dissipation per pole 7.2 W AC-3
12.5 W AC-1
Safety cover With
Mounting support Plate
Rail
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications GOST
RINA
DNV
LROS (Lloyds register of shipping)
BV
CCC
GL
Connections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
end
Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
Control circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
end
Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - without cable end
Power circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: flexible - without cable end
Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - with cable end
Power circuit : connector 2 cable(s) 4...16 mm² - cable stiffness: flexible - with cable end
Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: solid - without cable end
Power circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: solid - without cable end
Tightening torque Power circuit : 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
Power circuit : 9 N.m - on connector hexagonal 4 mm
Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Operating time 20...35 ms closing
6...20 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
2
Mechanical durability 4 Mcycles
Operating rate 3600 cyc/h at <= 60 °C
Complementary
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.85...1.1 Uc operational at 55 °C, AC 60 Hz
0.3...0.6 Uc drop-out at 55 °C, AC 50/60 Hz
0.8...1.1 Uc operational at 55 °C, AC 50 Hz
Inrush power in VA 245 VA at 20 °C (cos ϕ 0.75) 60 Hz
245 VA at 20 °C (cos ϕ 0.75) 50 Hz
Hold-in power consumption in VA 26 VA at 20 °C (cos ϕ 0.3) 60 Hz
26 VA at 20 °C (cos ϕ 0.3) 50 Hz
Heat dissipation 6...10 W at 50/60 Hz
Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
Insulation resistance > 10 MOhm for signalling circuit
Environment
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -5...60 °C
Ambient air temperature for storage -60...80 °C
Permissible ambient air temperature
around the device
-40...70 °C at Uc
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
Shocks contactor open 8 Gn for 11 ms
Vibrations contactor closed 3 Gn, 5...300 Hz
Shocks contactor closed 10 Gn for 11 ms
Height 127 mm
Width 85 mm
Depth 130 mm
Product weight 1.61 kg
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant  - since 0701  - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Need no specific recycling operations
Contractual warranty
Warranty period 18 months
3
Product data sheet
Dimensions Drawings
LC1D95E7
Dimensions
(1) Minimum electrical clearance
LC1 D80 D95
a 85 85
with LA4 D●2 135 135
with LA4 DB3 or LAD 4BB3 135 –
with LA4 DF, DT 142 142
b1
with LA4 DM, DW, DL 150 150
without cover or add-on blocks 125 125 c
with cover, without add-on blocks 130 130
with LAD N (1 contact) 150 150 c1
with LAD N or C (2 or 4 contacts) 158 158
c2 with LA6 DK10, LAD 6DK 170 170
with LAD T, R, S 178 178 c3
with LAD T, R, S and sealing cover 182 182
 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Business time
9:00-22:00
  • Email:support@rig123.com