Home » News center » 3WL1106-2AA36-1AA2 3WL1108-2AA36-1AA2 3WL1110-2AA36-1AA2
3WL1106-2AA36-1AA2 3WL1108-2AA36-1AA2 3WL1110-2AA36-1AA2
      Promulgator :admin      Time:2016-10-29
Inquiry Photo Description Model Technical parameters Certification Remark
3WL Draw-out 3P ACB without Overcurrent Release 3WL1106-2AA36-1AA2
Rated Current 630A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB without Overcurrent Release 3WL1108-2AA36-1AA2
Rated Current 800A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB without Overcurrent Release 3WL1110-2AA36-1AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB without Overcurrent Release 3WL1112-2AA36-1AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB without Overcurrent Release 3WL1116-2AA36-1AA2
Rated Current 1600A,Max. Rated Operating Voltage 690VAC

IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB without Overcurrent Release 3WL1220-2AA36-1AA2
Rated Current 2000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB without Overcurrent Release 3WL1225-2AA36-1AA2
Rated Current 2500A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1106-2AA46-1AA2
Rated Current 630A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1108-2AA46-1AA2
Rated Current 800A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1110-2AA46-1AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1112-2AA46-1AA2
Rated Current 1250A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1116-2AA46-1AA2
Rated Current 1600A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1220-2AA46-1AA2
Rated Current 2000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB without Overcurrent Release 3WL1225-2AA46-1AA2
Rated Current 2500A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB, with Overcurrent Release 3WL1106-2CB36-1AA2
Rated Current 630A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB, with Overcurrent Release 3WL1108-2CB36-1AA2
Rated Current 800A,Max. Rated Operating Voltage 690VAC

IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB, with Overcurrent Release 3WL1110-2CB36-1AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB, with Overcurrent Release 3WL1112-2CB36-1AA2
Rated Current 1250A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB, with Overcurrent Release 3WL1116-2CB36-1AA2
Rated Current 1600A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB, with Overcurrent Release 3WL1220-2CB36-1AA2
Rated Current 2000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
Business time
9:00-22:00
  • Email:support@rig123.com