3VL 3p MCCB ,70KA 3VL2710-2AB33-0AA0
Max. Operating Voltage690VAC, Rated Current IR 64-160A

Breaking Capacity(Ics = Icu; 415V),70KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL2706-2AB33-0AA0
Max. Operating Voltage690VAC, Rated Current IR 26-63A

Breaking Capacity(Ics = Icu; 415V),70KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL8716-1AB30-0AA0
Max. Operating Voltage690VAC, Rated Current IR 640-1600A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL7712-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 500-1250A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 

IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL7710-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 400-1000A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 

IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL6780-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 320-800A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 


IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL5763-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 252-630A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 


IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL4740-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 160-140A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL4731-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 128-315A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 


IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL3725-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 100-250A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 

IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL3720-1AB36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 80-200A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 


IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL2716-1AB33-0AA0
Max. Operating Voltage690VAC, Rated Current IR 64-160A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL2710-1AB33-0AA0
Max. Operating Voltage690VAC, Rated Current IR 40-100A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,40KA 3VL2706-1AB33-0AA0
Max. Operating Voltage690VAC, Rated Current IR 26-63A

Breaking Capacity(Ics = Icu; 415V),40KA ,Line Protection Overcurrent Release ETU10 
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL5763-2DC36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 500-630A

Breaking Capacity(Ics = Icu; 415V),70KA , Line Protection Overcurrent Release TM
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL5750-2DC36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 400-500A

Breaking Capacity(Ics = Icu; 415V),70KA , Line Protection Overcurrent Release TM
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL5740-2DC36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 315-400A

Breaking Capacity(Ics = Icu; 415V),70KA , Line Protection Overcurrent Release TM
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL5731-2DC36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 200-250A

Breaking Capacity(Ics = Icu; 415V),70KA , Line Protection Overcurrent Release TM
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL4740-2DC36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 315-400A

Breaking Capacity(Ics = Icu; 415V),70KA , Line Protection Overcurrent Release TM
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
3VL 3p MCCB ,70KA 3VL4731-2DC36-0AA0
Max. Operating Voltage690VAC, Rated Current IR 250-315A

Breaking Capacity(Ics = Icu; 415V),70KA , Line Protection Overcurrent Release TM
IEC 60947-1, EN 60-947-1 DIN VDE 0660 Part 100,IEC 60947-2, EN 60-947-2 DIN VDE 0660 Part 10 Other models also available, please contact us for details.
 