Specification | 03 | 06 | 10 | ||||
Max. working pressure (MPa) | P,X Oil ports P,X | 35 | |||||
Oil ports T(Y extl disch) | 30 | ||||||
Oil ports T(intll disch) | 10 | ||||||
Max. Flow | (L/min) | 250 | 500 | 650 | |||
Working fluid | Mineral oil;phosphate-ester | ||||||
Fluid temp | (℃) | -20~70 | |||||
Viscosity | (mm²/s) | 15~380 | |||||
Working press | (MPa) | 5, 10, 20, 31.5, 35 | |||||
Working voltage | (V) | DC | *AC | ||||
24 | 127, 220 | ||||||
Insulation grade | IP55 | ||||||
Cleanliness |
The maximum allowable cleanliness of the oil should be according to 9th degree of Standard NAS 1638.It is suggested that the minimum filter rating should be β 10 ≥75.
|
Specification | B1 | B2 | L1 | L2 | L3 | L4 | L5 | L6 | L7 | L8 |
GDYW-03 | 80 | 54 | 98.5 | 91.5 | 67 | 54 | 23.5 | 149.3 | 0 | 22.1 |
GDYW-06 | 100 | 69.8 | 122.2 | 117.5 | 83.7 | 66.7 | 26.5 | 161.8 | 23.8 | 11.1 |
GDYW-10 | 115 | 82.6 | 154.5 | 149.5 | 106.9 | 88.9 | 28.1 | 172.5 | 31.8 | 12.7 |
Specification | L9 | L10 | L11 | L12 | L13 | L14 | D | D1 | D2 | D3 |
GDYW-03 | 47.5 | 14 | 207 | 22.1 | 20 | 6 | 12 | 6 | M12 | 7 |
GDYW-06 | 55.6 | 11 | 219.5 | 33.3 | 25 | 6 | 25 | 6 | M16 | 7 |
GDYW-10 | 76.2 | 9.4 | 230.2 | 44.4 | 30 | 6 | 32 | 6 | M18 | 7 |