HCM
MPA-431THTU0
Delivery time:8-12 weeks
Cylinder type | Universal | ||||||
Cylinder types with adapter |
Round body cylinder Tie rod cylinder T-slot cylinders Festo cylinders DSBC SMC cylinders CP96 |
||||||
Measuring range | 431 mm 1) | ||||||
Housing length | 433 mm | ||||||
Output function | Analog, IO-Link | ||||||
Electrical wiring | DC 4-wire | ||||||
Analog output (voltage) | 0 V ... 10 V | ||||||
Analog output (current) | 4 mA ... 20 mA | ||||||
Enclosure rating |
IP65 2) IP67 IP68 |
||||||
IO-Link functions | Standard functions | ||||||
|
Supply voltage | 15 V DC ... 30 V DC | ||||||||||||||
Power consumption | 35 mA, without load | ||||||||||||||
Max. load resistance | ≤ 500 Ω Power Output, at 24 V | ||||||||||||||
Min. load resistance | ≥ 2 kΩ 1) | ||||||||||||||
Protection class | III | ||||||||||||||
Required magnetic field sensitivity, typ. | 2 mT ... 15 mT | ||||||||||||||
Resolution, typ. | 0.03 % FSR (max. ≥ 0.06 mm) 2) 3) | ||||||||||||||
Linearity error, typ. | 0.5 mm 4) | ||||||||||||||
Repeat accuracy, typ. | 0.06 % FSR (≥ 0.1 mm) 5) | ||||||||||||||
Sampling rate, typ. | 1.15 ms 6) | ||||||||||||||
Reverse polarity protection | Yes | ||||||||||||||
Short-circuit protection | Yes | ||||||||||||||
Status indicator LED | Yes | ||||||||||||||
Teach-in | Yes | ||||||||||||||
Ambient operating temperature | –20 °C ... +70 °C | ||||||||||||||
Shock and vibration resistance | 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm | ||||||||||||||
EMC | According to EN 60947-5-2 7) | ||||||||||||||
Connection type | Cable, 4-wire, 2 m | ||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
UL File No. | NRKH.E181493 & NRKH7.E181493 |
Communication interface | IO-Link V1.0.1 |
Communication Interface detail | COM2 |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 ... 3 = reserved Bit 4 ... 5 = position (after decimal point) Bit 6 ... 15 = position (before decimal point) |