Power contactor, AC-3 65 A, 30 kW / 400 V 1 NO + 1 NC, 230 V AC 50/60 Hz, 3-pole Size S2, screw terminals
|
product brand name
|
SIRIUS
|
product designation
|
Power contactor
|
product type designation
|
3RT2
|
General technical data
|
size of contactor
|
S2
|
product extension
|
|
● function module for communication
|
No
|
● auxiliary switch
|
Yes
|
power loss [W] for rated value of the current
|
|
● at AC in hot operating state
|
11.4 W
|
● at AC in hot operating state per pole
|
3.8 W
|
● without load current share typical
|
17.2 W
|
insulation voltage
|
|
● of main circuit with degree of pollution 3 rated value
|
690 V
|
● of auxiliary circuit with degree of pollution 3 rated value
|
690 V
|
surge voltage resistance
|
|
● of main circuit rated value
|
6 kV
|
● of auxiliary circuit rated value
|
6 kV
|
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1
|
400 V
|
shock resistance at rectangular impulse
|
|
● at AC
|
11.8g / 5 ms, 7.4g / 10 ms
|
shock resistance with sine pulse
|
|
● at AC
|
18.5g / 5 ms, 11.6g / 10 ms
|
mechanical service life (switching cycles)
|
|
● of contactor typical
|
10 000 000
|
● of the contactor with added electronically optimized auxiliary switch block typical
|
5 000 000
|
● of the contactor with added auxiliary switch block typical
|
10 000 000
|
reference code according to IEC 81346-2
|
Q
|
Substance Prohibitance (Date)
|
10/01/2014
|
Ambient conditions
|
installation altitude at height above sea level maximum
|
2 000 m
|
ambient temperature
|
|
● during operation
|
-25 ... +60 °C
|
● during storage
|
-55 ... +80 °C
|
relative humidity minimum
|
10 %
|
relative humidity at 55 °C according to IEC 60068-2-30 maximum
|
95 %
|
Main circuit
|
number of poles for main current circuit
|
3
|
number of NO contacts for main contacts
|
3
|
operating voltage
|
|
● at AC-3 rated value maximum
|
690 V
|
● at AC-3e rated value maximum
|
690 V
|
operational current
|
|
● at AC-1 at 400 V at ambient temperature 40 °C rated value
|
80 A
|
● at AC-1
|
|
— up to 690 V at ambient temperature 40 °C rated value
|
80 A
|
— up to 690 V at ambient temperature 60 °C rated value
|
70 A
|
● at AC-3
|
|
— at 400 V rated value
|
65 A
|
— at 500 V rated value
|
65 A
|
— at 690 V rated value
|
47 A
|
● at AC-3e
|
|
— at 400 V rated value
|
65 A
|
— at 500 V rated value
|
65 A
|
— at 690 V rated value
|
47 A
|
● at AC-4 at 400 V rated value
|
55 A
|
● at AC-5a up to 690 V rated value
|
70.4 A
|
● at AC-5b up to 400 V rated value
|
53.9 A
|
● at AC-6a
|
|
— up to 230 V for current peak value n=20 rated value
|
56.9 A
|
— up to 400 V for current peak value n=20 rated value
|
56.9 A
|
— up to 500 V for current peak value n=20 rated value
|
56.9 A
|
— up to 690 V for current peak value n=20 rated value
|
47 A
|
● at AC-6a
|
|
— up to 230 V for current peak value n=30 rated value
|
38 A
|
— up to 400 V for current peak value n=30 rated value
|
38 A
|
— up to 500 V for current peak value n=30 rated value
|
38 A
|
— up to 690 V for current peak value n=30 rated value
|
38 A
|
minimum cross-section in main circuit at maximum AC-1 rated value
|
25 mm²
|
operational current for approx. 200000 operating cycles at AC-4
|
|
● at 400 V rated value
|
28 A
|
● at 690 V rated value
|
22 A
|
operational current
|
|
● at 1 current path at DC-1
|
|
— at 24 V rated value
|
55 A
|
— at 110 V rated value
|
4.5 A
|
— at 220 V rated value
|
1 A
|
— at 440 V rated value
|
0.4 A
|
— at 600 V rated value
|
0.25 A
|
● with 2 current paths in series at DC-1
|
|
— at 24 V rated value
|
55 A
|
— at 110 V rated value
|
45 A
|
— at 220 V rated value
|
5 A
|
— at 440 V rated value
|
1 A
|
— at 600 V rated value
|
0.8 A
|
● with 3 current paths in series at DC-1
|
|
— at 24 V rated value
|
55 A
|
— at 110 V rated value
|
55 A
|
— at 220 V rated value
|
45 A
|
— at 440 V rated value
|
2.9 A
|
— at 600 V rated value
|
1.4 A
|
● at 1 current path at DC-3 at DC-5
|
|
— at 24 V rated value
|
35 A
|
— at 110 V rated value
|
2.5 A
|
— at 220 V rated value
|
1 A
|
— at 440 V rated value
|
0.1 A
|
— at 600 V rated value
|
0.06 A
|
● with 2 current paths in series at DC-3 at DC-5
|
|
— at 24 V rated value
|
55 A
|
— at 110 V rated value
|
25 A
|
— at 220 V rated value
|
5 A
|
— at 440 V rated value
|
0.27 A
|
— at 600 V rated value
|
0.16 A
|
● with 3 current paths in series at DC-3 at DC-5
|
|
— at 24 V rated value
|
55 A
|
— at 110 V rated value
|
55 A
|
— at 220 V rated value
|
25 A
|
— at 440 V rated value
|
0.6 A
|
— at 600 V rated value
|
0.35 A
|
operating power
|
|
● at AC-2 at 400 V rated value
|
30 kW
|
● at AC-3
|
|
— at 230 V rated value
|
18.5 kW
|
— at 400 V rated value
|
30 kW
|
— at 500 V rated value
|
37 kW
|
— at 690 V rated value
|
37 kW
|
● at AC-3e
|
|
— at 230 V rated value
|
18.5 kW
|
— at 400 V rated value
|
30 kW
|
— at 500 V rated value
|
37 kW
|
— at 690 V rated value
|
37 kW
|
operating power for approx. 200000 operating cycles at AC-4
|
|
● at 400 V rated value
|
14.7 kW
|
● at 690 V rated value
|
20 kW
|
operating apparent power at AC-6a
|
|
● up to 230 V for current peak value n=20 rated value
|
22.6 kVA
|
● up to 400 V for current peak value n=20 rated value
|
39.4 kVA
|
● up to 500 V for current peak value n=20 rated value
|
49.2 kVA
|
● up to 690 V for current peak value n=20 rated value
|
56.1 kVA
|
operating apparent power at AC-6a
|
|
● up to 230 V for current peak value n=30 rated value
|
15.1 kVA
|
● up to 400 V for current peak value n=30 rated value
|
26.2 kVA
|
● up to 500 V for current peak value n=30 rated value
|
32.8 kVA
|
● up to 690 V for current peak value n=30 rated value
|
45.3 kVA
|
short-time withstand current in cold operating state up to 40 °C
|
|
● limited to 1 s switching at zero current maximum
|
1 055 A; Use minimum cross-section acc. to AC-1 rated value
|
● limited to 5 s switching at zero current maximum
|
730 A; Use minimum cross-section acc. to AC-1 rated value
|
● limited to 10 s switching at zero current maximum
|
520 A; Use minimum cross-section acc. to AC-1 rated value
|
● limited to 30 s switching at zero current maximum
|
336 A; Use minimum cross-section acc. to AC-1 rated value
|
● limited to 60 s switching at zero current maximum
|
272 A; Use minimum cross-section acc. to AC-1 rated value
|
no-load switching frequency
|
|
● at AC
|
5 000 1/h
|
operating frequency
|
|
● at AC-1 maximum
|
800 1/h
|
● at AC-2 maximum
|
400 1/h
|
● at AC-3 maximum
|
700 1/h
|
● at AC-3e maximum
|
700 1/h
|
● at AC-4 maximum
|
200 1/h
|
Control circuit/ Control
|
type of voltage of the control supply voltage
|
AC
|
control supply voltage at AC
|
|
● at 50 Hz rated value
|
230 V
|
● at 60 Hz rated value
|
230 V
|
operating range factor control supply voltage rated value of magnet coil at AC
|
|
● at 50 Hz
|
0.8 ... 1.1
|
● at 60 Hz
|
0.85 ... 1.1
|
apparent pick-up power of magnet coil at AC
|
|
● at 50 Hz
|
210 VA
|
● at 60 Hz
|
188 VA
|
inductive power factor with closing power of the coil
|
|
● at 50 Hz
|
0.69
|
● at 60 Hz
|
0.65
|
apparent holding power of magnet coil at AC
|
|
● at 50 Hz
|
17.2 VA
|
● at 60 Hz
|
16.5 VA
|
inductive power factor with the holding power of the coil
|
|
● at 50 Hz
|
0.36
|
● at 60 Hz
|
0.39
|
closing delay
|
|
● at AC
|
10 ... 80 ms
|
opening delay
|
|
● at AC
|
10 ... 18 ms
|
arcing time
|
10 ... 20 ms
|
control version of the switch operating mechanism
|
Standard A1 - A2
|
Auxiliary circuit
|
number of NC contacts for auxiliary contacts instantaneous contact
|
1
|
number of NO contacts for auxiliary contacts instantaneous contact
|
1
|
operational current at AC-12 maximum
|
10 A
|
operational current at AC-15
|
|
● at 230 V rated value
|
10 A
|
● at 400 V rated value
|
3 A
|
● at 500 V rated value
|
2 A
|
● at 690 V rated value
|
1 A
|
operational current at DC-12
|
|
● at 24 V rated value
|
10 A
|
● at 48 V rated value
|
6 A
|
● at 60 V rated value
|
6 A
|
● at 110 V rated value
|
3 A
|
● at 125 V rated value
|
2 A
|
● at 220 V rated value
|
1 A
|
● at 600 V rated value
|
0.15 A
|
operational current at DC-13
|
|
● at 24 V rated value
|
10 A
|
● at 48 V rated value
|
2 A
|
● at 60 V rated value
|
2 A
|
● at 110 V rated value
|
1 A
|
● at 125 V rated value
|
0.9 A
|
● at 220 V rated value
|
0.3 A
|
● at 600 V rated value
|
0.1 A
|
contact reliability of auxiliary contacts
|
1 faulty switching per 100 million (17 V, 1 mA)
|
UL/CSA ratings
|
full-load current (FLA) for 3-phase AC motor
|
|
● at 480 V rated value
|
65 A
|
● at 600 V rated value
|
52 A
|
yielded mechanical performance [hp]
|
|
● for single-phase AC motor
|
|
— at 110/120 V rated value
|
5 hp
|
— at 230 V rated value
|
10 hp
|
● for 3-phase AC motor
|
|
— at 200/208 V rated value
|
20 hp
|
— at 220/230 V rated value
|
20 hp
|
— at 460/480 V rated value
|
50 hp
|
— at 575/600 V rated value
|
50 hp
|
contact rating of auxiliary contacts according to UL
|
A600 / P600
|
Short-circuit protection
|
design of the fuse link
|
|
● for short-circuit protection of the main circuit
|
|
— with type of coordination 1 required
|
gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
|
— with type of assignment 2 required
|
gG: 125A (690V,100kA), aM: 63A (690V,100kA), BS88: 100A (415V,80kA)
|
● for short-circuit protection of the auxiliary switch required
|
gG: 10 A (500 V, 1 kA)
|
Installation/ mounting/ dimensions
|
mounting position
|
+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
|
fastening method
|
screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
|
● side-by-side mounting
|
Yes
|
height
|
114 mm
|
width
|
55 mm
|
depth
|
130 mm
|
required spacing
|
|
● with side-by-side mounting
|
|
— forwards
|
10 mm
|
— upwards
|
10 mm
|
— downwards
|
10 mm
|
— at the side
|
0 mm
|
● for grounded parts
|
|
— forwards
|
10 mm
|
— upwards
|
10 mm
|
— at the side
|
6 mm
|
— downwards
|
10 mm
|
● for live parts
|
|
— forwards
|
10 mm
|
— upwards
|
10 mm
|
— downwards
|
10 mm
|
— at the side
|
6 mm
|
Connections/ Terminals
|
type of electrical connection
|
|
● for main current circuit
|
screw-type terminals
|
● for auxiliary and control circuit
|
screw-type terminals
|
● at contactor for auxiliary contacts
|
Screw-type terminals
|
● of magnet coil
|
Screw-type terminals
|
type of connectable conductor cross-sections
|
|
● for main contacts
|
|
— solid or stranded
|
2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
|
— finely stranded with core end processing
|
2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
|
● at AWG cables for main contacts
|
2x (18 ... 2), 1x (18 ... 1)
|
connectable conductor cross-section for main contacts
|
|
● finely stranded with core end processing
|
1 ... 35 mm²
|
connectable conductor cross-section for auxiliary contacts
|
|
● solid or stranded
|
0.5 ... 2.5 mm²
|
● finely stranded with core end processing
|
0.5 ... 2.5 mm²
|
type of connectable conductor cross-sections
|
|
● for auxiliary contacts
|
|
— solid or stranded
|
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
|
— finely stranded with core end processing
|
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
|
● at AWG cables for auxiliary contacts
|
2x (20 ... 16), 2x (18 ... 14)
|
AWG number as coded connectable conductor cross section
|
|
● for main contacts
|
18 ... 1
|
● for auxiliary contacts
|
20 ... 14
|
Safety related data
|
product function
|
|
● mirror contact according to IEC 60947-4-1
|
Yes
|
● positively driven operation according to IEC 60947-5-1
|
No
|
B10 value with high demand rate according to SN 31920
|
1 000 000
|
proportion of dangerous failures
|
|
● with low demand rate according to SN 31920
|
40 %
|
● with high demand rate according to SN 31920
|
73 %
|
failure rate [FIT] with low demand rate according to SN 31920
|
100 FIT
|
protection class IP on the front according to IEC 60529
|
IP20
|
touch protection on the front according to IEC 60529
|
finger-safe, for vertical contact from the front
|
suitability for use
|
|
● safety-related switching OFF
|
Yes
|
Certificates/ approvals
|
Downloads and manuals
|
|
Further information
|
Information- and Downloadcenter (Catalogs, Brochures,…)
|
Industry Mall (Online ordering system)
|
Cax online generator
|
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
|
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
|
Characteristic: Tripping characteristics, I²t, Let-through current
|
Further characteristics (e.g. electrical endurance, switching frequency)
|
|
|
|
last modified:
|
2/15/2022
|
Date
5/2/2022
|
Subject to change without notice
© Copyright Siemens 2022
|