Model | BYLZ-02-*-* | BYLZ-03-*-* | BYLZ-06-250*-* | ||
Maximum pressure | (MPa) | 31.5 | |||
Maximum flow | (l/min) | 63 | 160 | 250 | |
Flow range | (l/min) | 1-63 | 1-160 | 2.5-250 | |
Pressure control |
Range current | (mA) | 800 | ||
Coil resistance | (Ω) | 19.5 | 43.5 | 43.5 | |
P Differential | (MPa) | 0.6 | 0.6 | 0.7 | |
Hystersis | (%) | <5 | <7 | <7 | |
Repeatability | (%) | <1 | |||
Flow control | Pressure Range | (MPa) | 16:1.2-16 | 16:1.4-16 | 16:1.5-16 |
25:1.2-25 | |||||
31.5:1.2-31.5 | 25:1.4-25 | 25:1.5-25 | |||
Range current | (mA) | 800 | |||
Coil resistance | (Ω) | 10 | 10 | 10 | |
Hystersis | (%) | <3 | |||
Repeatability | (%) | <1 | |||
Weight | (Kg) | 7 | 16 | 30 | |
Cleanliness | Filter is recommended for the highest fluid pollution degree;the lowest specific filtration resistance according to ISO 4406(c)20/18/15. |