HCM(YMX)
XCKN2108P20
Delivery time:in stock
MAIN | |
---|---|
Range of product | Telemecanique Limit switches XC Standard |
Series name | Standard format |
Product or component type | Limit switch |
Device short name | XCKN |
Sensor design | Compact |
Body type | Fixed |
Head type | Multi-directional head |
Material | Plastic |
Body material | Plastic |
Head material | Plastic |
Fixing mode | By the body |
Movement of operating head | Multi-directional |
Type of operator | Spring return spring rod |
Type of approach | Multi-directional approach |
Cable entry | 1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm |
Number of poles | 2 |
Contacts type and composition | 1 NC + 1 NO |
Contact operation | Snap action |
COMPLEMENTARY | |
Switch actuation | By any moving part |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
Contacts insulation form | Zb |
Positive opening | Without |
Minimum torque for tripping | 0.13 N.m |
Maximum actuation speed | 1 m/s |
Contact code designation |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A |
[Ui] rated insulation voltage |
300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 |
Short-circuit protection | 10 A cartridge fuse, type gG |
Electrical durability |
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Mechanical durability | 5000000 cycles |
Width | 30 mm |
Height | 183 mm |
Depth | 30 mm |
Net weight | 0.175 kg |
Terminals description ISO n°1 |
(21-22)NC (13-14)NO |
ENVIRONMENT | |
Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration resistance | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP65 conforming to IEC 60529 |
IK degree of protection | IK04 conforming to EN 50102 |
Overvoltage category |
Class II conforming to IEC 61140 Class II conforming to NF C 20-030 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…70 °C |
Protective treatment | TC |
Product certifications |
CCC CSA UL |
Standards |
EN 60204-1 IEC 60204-1 IEC 60947-5-1 CSA C22.2 No 14 UL 508 EN 60947-5-1 |